🔋 Power Up Your Savings!
The Aeotec Zangenamperemeter is a cutting-edge wireless energy monitor that provides real-time tracking of electricity usage with 99% accuracy. Designed for 3-phase systems, it includes three clamps capable of measuring up to 60 amps each, ensuring comprehensive monitoring of multiple loads. With a wireless range of up to 492 feet and Z-Wave Plus certification, this device is perfect for tech-savvy homeowners looking to optimize their energy consumption.
Manufacturer | Aeotec |
Part number | ZW095-C 3P4 60A |
Item Weight | 510 g |
Product Dimensions | 6 x 10 x 3.5 cm; 510 g |
Item model number | ZW095-C 3P4 60A |
Size | Medium |
Color | White |
Item Package Quantity | 1 |
Number Of Pieces | 1 |
Included components | Back Mount Plate x 1, Manual x 1, Clamp x 3, Home Energy Meter Monitor x 1 |
Batteries Included? | No |
Batteries Required? | No |
K**
Wykorzystanie przy fotowoltaice bardzo ograniczone!
W przeciwieństwie do tego co sugeruje instrukcja urządzenie nie może podawać "ujemnych" wartości poboru mocy. Z HC2 nawet pomimo ustawienia:1 = report positive/negative power, report the algebraic sum energy;nie jest podawana "ujemna" moc chwilowa!Podawany jest ujemny prąd, podawane napięcie - ale przy współczynniku mocy różnym znacząco od 1 nie jest to wystarczające. Z dyskusji dotyczących HomeAssistant wynika, że komuś udało się uzyskać ujemną moc. Jednak zdaje się, że to zależy od bramki Z-Wave.Oczywiście positive/negative power nie działa także w opcji:2 = report positive/negative power, only report energy positive part (consuming electricity);ta zaś jest optymalna dla obecnych zasad dla FV w Polsce (1-ka powoduje odejmowanie zużycia a to nie jest prawidłowe pomijając bilansowanie międzyfazowe).Podsumowując, wykorzystanie urządzenia przy pomiarze zarówno zużycia jak i produkcji wymaga niesamowitych kombinacji. Z całą pewnością urządzenie nie działa tak jak to opisano w instrukcji Potwierdził to nawet sam serwis. Ujemna moc jest zerowana, właściwie kombinować można jedynie próbkując zmiany góra/dół sumy energii. Dodatkowo przy skonfigurowaniu przesyłania danych z dużą częstotliwością (oraz wszystkiego co się da, czyli prądu, energii, napięcia) pojawiają się problemy z przeciążeniem sieci. Na plus należy dodać, że na chwilę obecną, urządzenia, które nie powinny sprawiać takich problemów są przynajmniej 2x droższe (i nie są to urządzenia z-wave, choć umożliwiają oczywiście integrację w systemach typu HomeAssistant itp.)
G**.
Energy Monitor
Lo uso per monitorare la linea del Fotovoltaico con HA. Funziona bene.
D**
Aeotec energimätare
Lätt att koppla in i centralen. Fick försöka ett antal gånger innan den anslöt till hubben. Fungerar enligt beskrivning.
J**N
Muy dificil de configurar y muy escasa información
Para que funcione, es necesario comprar a parte un hub.No tiene app propia, y es necesario utilizar smartthings de samsung. La información que da, es limitadisima.Da solamente el consumo acumulado y el consumo instantáneo, con mucho retraso (actualiza cada 5 minutos).Los 3 sensores, no Dan la información por separado, por lo que no es posible realizar mediciones personalizadas.Recomiendan el uso de la aplicación de pago para pc Homeseer. La configuración de esta aplicación, no esta al alcance de usuarios medios debido a su extrema complejidad.No recomendable
R**Y
3 Clamps on Single phase... yes you can. Smarthings... Yes!
I bought this item hoping it would work with smartthings and that I could use this on my new home which will be a single phase supplied house. I plan to monitor multiple feeds (Solar, Mains and A2W system). With some testing over the weekend here are some pointers if you're in the same position:Single Phase with 3 clamp model:- This works perfectly but I was surprised to see the unit has 3 sets AC wires to power the device. Each cable powers 1 clamp only. I bundled all 3 cables into one plug for testing purpose but will use a junction box when I install this permanently. I tested plugging just one AC cable in and then two and I received reading from just one or two clamps in the testing. You will need to wire in all 3 unfortunatly but thats not a deal breaker for me. REMEMBER: this is for when using the device on a single phase feed! Do not bundle the cables in a 3-phase installation- This may be obvious to some but I have seen reviews saying this devices clamps do not fit UK cabling. Well in Ireland we use the same 220v and the clamp fits perfectly to my mains supply (60+amp). Remember the clamp goes on the live wire only so if you are placing its on another source you may need to strip the cable back a bit. It's not meant to wrap around all wires (L,N,G) of a device, just live.Smartthings:- A bit of a challange here but I used the device handler from "ClassicGod" found in the smartthings forums. There is a long thread on this and about post 220 there is mention of using the Z-Wave Tweaker which I had to use to get each of the clamps reporting back to the app. Took a bit of work but this is now working perfectly. You will need to adjust the report rates if you are missing some data as the device can flood the hub with lots of data if left uncontolled. I'm making this seem complicated but it honestly took 30-45mins to get this humming away nicely. Follow the instructions from the handler and the form. This is a Gen 5 device.Other notes:- Obvious to those smarter than me, but if you put clamp 1 on the main feed and then clamp 2 on the immersion, for example, the total readout for the device will be both added together (effectly counting your immersion twice!). Be careful if you connect the clamps in series as your device total will be complely wrong!!